|       Features:- 12.1" color TFT screen
 - Multi‐channel display
 - Big font interface
 - ST and arrhythmia analysis
 - Drug dose calculation and titration table
 - OxyCRG dynamic view display
 - Respiration monitoring with apnea alarms
 - Alarm review, arrhythmia review
 - Patient info. Input
 - Anti‐defibrillation design
 - NIBP over pressure protection
 - Plug‐in rechargeable battery, AC/DC available.
 - Supporting wire or wireless network.
 Technical Specifications ECGLead Mode 5 Leads (R, L, F, N, C or RA, LA, LL, RL,V)
 Lead selection I, II, III, avR, avL, avF, V
 Wavef orm 2 ch
 Lead mode 3 Leads ( R, L, F or RA, LA, LL)
 Lead selection I, II, III,
 Wave form 1 ch
 Gain 2.5mm/mV, 5.0mm/mV, 10mm/mV,20mm/mV, auto
        HR and Alarm Range Adult 15 ~ 300 bpm
 Neo/Ped 15 ~ 350 bpm
 Accuracy ±1% or±1bpm, which is greater
 Resolution 1 bpm
 Sensitivity > 200 (uVp-p)
 Differential Input Impedance > 5 MΩ
 CMRR Monitor > 105 dB
 Operation > 105 dB
 Diagnosis > 85 dB
 Electrode offset potential ±300mV
 Leakage Current < 10 uA
 Baseline Recovery < 3 S After Defi.
 ECG Signal Range ±8 m V ( Vp-p )
 Bandwidth Surgery 1 ~ 20 Hz
 Monitor 0.5 ~ 40 Hz
 Diagnostic 0.05 ~ 130 Hz
 Calibration Signal 1 (mVp-p), Accuracy:5%
 ST Segment Monitoring Range Measure and Alarm -2.0 ~ +2.0 mV
 ARR Detecting Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2,BRADY, MISSED BEATS,
  PNP, PNC,Alarm Available,Review Available
 
 Respiration
 Method Impedance between R-F(RA-LL)
 Differential Input Impedance > 2.5 MΩ
 Measuring Impedance Range 0.3~3 Ω
 Base line Impedance Range 200~4 KΩ
 Bandwidth 0.1~2.5Hz
 Resp. Rate Measuring and Alarm Range
 Adult 0 ~ 120 Brpm
 Neo/Ped 0 ~ 150 Brpm
 Resolution 1 Brpm
 Accuracy ±2 Brpm
 Apnea Alarm 10 ~ 40 S
 
 NIBP
 Method Oscillometric
 Mode Manual, Auto, STAT
 Measuring Interval in AUTO Mode 1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min)
 Measuring Period in STAT Mode 5 Min
 Pulse Rate Range 40 ~ 240 bpm
 Alarm Type SYS, DIA, MEAN
 Measuring and alarm range Adult Mode
 SYS 40 ~ 270 mmHg
 DIA 10 ~ 215 mmHg
 MEAN 20 ~ 235 mmHg
 Pediatric Mode
 SYS 40 ~ 200 mmHg
 DIA 10 ~ 150 mmHg
 MEAN 20 ~ 165 mmHg
 Neonatal Mode
 SYS 40 ~ 135 mmHg
 DIA 10 ~ 100 mmHg
 MEAN 20 ~ 110 mmHg
 Resolution 1mmHg
 Accuracy Maximum Mean error ±5mmHg
 Maximum Standard deviation ±8mmHg
 Overpressure Protection Adult Mode 297±3 mmHg
 Pediatric Mode 240±3 mmHg
 Neonatal Mode 147±3 mmHg
 SpO2Measuring Range 0 ~ 100 %
 Alarm Range 0 ~ 100 %
 Resolution 1 %
 Accuracy 70% ~ 100% 2 %
 0% ~ 69% unspecified
 Actualization interval about 1 Sec.
 Alarm Delay 10 Sec.
 Pulse Rate Measuring and Alarm Range 20~300 bpm
 Resolution 1bpm
 Accuracy ±3bpm
 
 TEMP
 Channel 2
 Measuring and Alarm Range 0 ~ 50 ℃
 Resolution 0.1 ℃
 Accuracy ±0.2 ℃
 Actualization intervalabout 1 Sec.
 Average Time Constant < 10 Sec.
 IBPLabel ART, PA, CVP, RAP, LAP, ICP, P1, P2
 Measuring and alarm range ART 0 ~ 300 mmHg
 PA -6 ~ 120 mmHg
 CVP/RAP/LAP/ICP-10 ~ 40 mmHg
 P1 / P2-10 ~ 300 mmHg
 Press Sensor Sensitivity 5 uV/V/mmHg
 Impedance 300-3000Ω
 Resolution 1 mmHg
 Accuracy ±2% or 1mmHg which is greater
 Actualization interval about 1 secretary
 Standard: ECG, Respiration, NIBP, SpO2, Pulse Rate, TemperatureOptional: Nellcor SpO2, EtCO2, IBP,TEMP-2, Thermal Recorder,Wall Mount,Trolly,Central station
 |  |